Page 153 - LIT-18626-13-46
P. 153

SportsBoat_F4X13.book  Page 146  Friday, May 21, 2021  4:49 PM



                                                                       Trouble recovery


                        TIP:
                                                                                         5
                        Because the port and starboard engines op-                          2
                        erate at the same engine speed when the sin-  4
                        gle lever mode or DRiVE mode is activated,
                        the difference in the amount of throttle for the
                        engines cannot be used to steer the boat.

                        Jump-starting
                             WARNING                                 3            1
                        Severe injury or death may result if you ig-
                                                              1  Positive (+) terminal of the dead battery
                        nore any of the following:
                                                              2  Positive (+) jumper cable
                         If the blowers will not operate, ventilate  3  Engine hanger
                          the engine compartment by opening the  4  Negative (–) jumper cable
                          engine hood for several minutes before  5  Booster battery
                          attempting a jump-start.
                         Do not connect the negative (–) jumper  (4) Start the engines, and then disconnect
                          cable to the negative (–) terminal of the  the jumper cables by reversing the above
                          dead  battery. Sparks could ignite bat-  steps.  NOTICE: Do  not push the
                          tery or fuel vapors, which could cause  “START/STOP” button for more than 5
                          an explosion.                          seconds. If the engine does not start
                                                                 in   5   seconds,   release  the
                        If the  boat battery  runs down,  the engines
                                                                 “START/STOP” button and try again
                        can be started in an emergency using a 12-
                                                                 after 15 seconds.  Continuous crank-
                        volt booster battery and jumper cables.
                                                                 ing for more than 5 seconds will dis-
                        To connect the jumper cables:
                                                                 charge the battery and  the  engines
                        (1) Connect the positive (+) terminal of the
                                                                 will not start. The starter motors may
                            dead battery to the positive (+) terminal
                                                                 also be damaged if they are engaged
                            of the booster battery with the positive
                                                                 continuously for more than 5 seconds.
                            (+) jumper cable.
                        (2) Connect one  end of the negative  (–)
                            jumper cable to the negative (–) terminal
                            of the booster battery.
                        (3) Connect the other end of the negative (–)
                            jumper cable to  an engine hanger.
                            NOTICE: Be sure all connections are
                            secure and correct before attempting
                            to start the engines. Any wrong con-
                            nection may damage  the  electrical
                            system.





                                                                                             146