Page 115 - LIT-18626-15-36
P. 115

SportsBoat_F6D11.book  Page 105  Friday, May 24, 2024  5:40 PM



                                                                Pre-operation checks

                        222XE: Start the engines before performing  Throttle/shift paddle checks (222XD)
                        the following checks. NOTICE: Do not run  Operate  the throttle/shift paddles several
                        the engines over 4000 r/min on land. Also,  times to make sure that operation is smooth
                        do not run the engines for more than 15  throughout the whole range. Also, make sure
                        seconds without supplying water, other-  that the throttle/shift paddles return automat-
                        wise, the engines could overheat and/or  ically to  their original positions  when re-
                        seize.                                leased.
                        Check that the shift gates are slightly above
                        the shift gate neutral position when the re-   1
                        mote control levers are in the forward posi-
                        tion, and that the shift gates are in the fully
                        open position when the remote control levers
                        are moved farther forward.
                        Fully open position
                          1
                                                                       1
                                                              1  Throttle/shift paddle

                          2                                   Fire extinguisher check
                                                              As an inboard boat less than 26 feet in length,
                                                              your boat must be fitted with one 5-B (B-1)
                                                              type fire extinguisher when navigating waters
                                                              controlled by the U.S. Coast Guard. In addi-
                        1  Shift gate                         tion, most state and local boating laws re-
                        2  Jet thrust nozzle                  quire that the craft carry a USCG-approved
                                                              fire extinguisher whenever the boat is operat-
                        Check that the shift gates are in the fully
                                                              ed.
                        closed position when the remote control le-
                                                              Make sure at least one fire extinguisher is
                        vers are in the reverse position.
                                                              aboard and full; two fire extinguishers are
                        Fully closed position
                                                              recommended. See the instructions supplied
                                                              by the  extinguisher manufacturer to deter-
                                                              mine the indication of the condition.
                          1
                                                              A fire extinguisher is not standard equipment
                                                              with this boat. If you do not have a fire extin-
                                                              guisher,  contact your local  Yamaha Boat
                                                              Dealer or fire extinguisher dealer for one
                                                              meeting the proper specifications.



                        1  Shift gate


                                                                                             105
   110   111   112   113   114   115   116   117   118   119   120